Home Print this page Email this page Users Online: 326
Home About us Editorial board Search Ahead of print Current issue Archives Submit article Instructions Subscribe Contacts Login 
ORIGINAL ARTICLE
Year : 2021  |  Volume : 9  |  Issue : 2  |  Page : 59-63

Comparison of photorefraction by photoscreener (PlusoptiXA12R) with autorefractometer and cycloplegic retinoscopy in children between 5 and 15 years


1 Department of Ophthalmology, Sankara Eye Hospital, Coimbatore, Tamil Nadu, India
2 Department of Pediatric Ophthalmology and Strabismus, Sankara Eye Hospital, Coimbatore, Tamil Nadu, India

Correspondence Address:
V Rajesh Prabu
Sankara Eye Hospital, 16.A, Sathy Road, Sivanandhapuram, Coimbatore - 641 035, Tamil Nadu, India
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jcor.jcor_63_20

Rights and Permissions

Aim: The aim of the study is to compare the photorefraction values by photoscreener (PlusoptiXA12R, PO) with those of autorefractometer (AR) (TOPCON RM800) and cycloplegic retinoscopy (CR) in children. Methods: It was an observational cross-sectional analytical study with a sample size of 1000 eyes conducted over a duration of one year in a tertiary eye care center. Children in the age group of 5–15 years with refractive error were screened using photoscreener and AR in noncycloplegic state followed by CR. Interclass correlation and agreement were assessed for measurements taken by all three modalities. Sensitivity and specificity were analyzed. P < 0.05 was taken significant for all statistical tests. Positive likelihood ratio, negative likelihood ratio, positive predictive value, and negative predictive value were statistically analyzed. Receiver operative characteristic curve and area under the curve were plotted. Results: Refraction measurements by photoscreener had a strong positive correlation with measurements from CR and AR. Bland-Altman plots depicted the agreement for measurements taken by all three modalities. Sensitivity and specificity of values were high for photoscreener (PlusoptiXA12R) when compared with CR and AR. Conclusion: We conclude that photoscreener is a reliable alternative to AR and CR for detection of refractive error in children between 5 and 15 years of age.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed1322    
    Printed44    
    Emailed0    
    PDF Downloaded118    
    Comments [Add]    

Recommend this journal