Home Print this page Email this page Users Online: 1132
Home About us Editorial board Search Ahead of print Current issue Archives Submit article Instructions Subscribe Contacts Login 
ORIGINAL ARTICLE
Year : 2021  |  Volume : 9  |  Issue : 3  |  Page : 118-122

Comparison of the influx of bacterial-sized particles in single plane versus multiplane femtosecond laser incisions


1 Department of Ophthalmology, King Khaled Eye Specialist Hospital, Riyadh, Saudi Arabia; Cataract and Refractive Surgeon, Wellish Vision Institute, Las Vegas, NV, USA
2 Department of Ophthalmology, King Khaled Eye Specialist Hospital, Riyadh, Saudi Arabia
3 Department of Ophthalmology, King Khaled Eye Specialist Hospital, Riyadh; Department of Ophthalmology, Faculty of Medicine, University of Jeddah, Jeddah, Saudi Arabia
4 Department of Ophthalmology, King Khaled Eye Specialist Hospital, Riyadh; Department of Ophthalmology, College of Medicine, Qassim University, Burydah, Saudi Arabia

Correspondence Address:
Rajiv Khandekar
King Khaled Eye Specialist Hospital, Riyadh
Saudi Arabia
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jcor.jcor_135_20

Rights and Permissions

Purpose: To present ingress of dye particles that are of size of bacteria though single and multi-planar corneal incision created by femtosecond laser in donor eyes. Setting: A tertiary eye Hospital, Central Saudi Arabia. Design: Ex vivo experimental study. Methods: This ”as ex vivo experimental study. Eyes acquired from an eye-bank that ”ere deemed unsuitable for corneal transplant ”ere used to create single as ”ell as multi-planar corneal incision using LenSx femtosecond laser. Each eye received single plane (SP) and one of the multiplanes either default multi-planar (DMP) or a right-angled multi-planar (RAMP) incision. After maintaining intraocular pressure (IOP), India ink ”as placed on the ”ound. Length and ”idth of ingress dye ”ere photographed and measured for different types of ”ound. Results: A total of 10 eyes ”ere used for this experiment. At physiologic IOP, the median and 25% quartile of length”ise invasion ”as 0.29 mm for the SP group (10 eyes), 0.23 mm for the DMP group (5 eyes), and 0.22 mm for the RAMP group (5 eyes). The difference of ingress bet”een the SP and RAMP groups as ”ell as SP and DMP group ”ere statistically significant (P = 0.005). The difference in length”ise and area ”ise invasion bet”een the DMP and RAMP groups ”as not statistically significant (P = 0.5). Conclusion: Bacteria size particle ingress seems to be more likely through SP incision compared to multi-plane corneal incisions created ”ith a femtosecond laser.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed1419    
    Printed70    
    Emailed0    
    PDF Downloaded123    
    Comments [Add]    

Recommend this journal