Role of B-scan ultrasonography in preoperative evaluation of posterior segment in dense cataract: An observational study in a tertiary eye care hospital


Department of Ophthalmology, Yenepoya Medical College, Mangalore, Karnataka, India

Correspondence Address:
Anupama Bappal
Department of Ophthalmology, Yenepoya Medical College, Mangalore, Karnataka
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jcor.jcor_160_21

Rights and Permissions

Context: B-scan ultrasonography is a diagnostic tool available for use in dense cataracts that gives vital information on vitreous, retina, choroid, and sclera. Aims: This study was planned to determine the abnormalities of the posterior segment in the presence of dense cataracts using B-scan ultrasonography and to determine the sensitivity and specificity of it. Settings and Design: Observational study design. Subjects and Methods: This observational study was done in patients with dense cataracts of any age. All the study participants underwent anterior segment evaluation, vision assessment, and posterior segment evaluation using B-scan ultrasonography. After cataract surgery, fundus evaluation of these patients was done. Pearson Chi-square test was used for assessing sensitivity and specificity of B-scan ultrasonography. Results: A total of 184 eyes of 161 patients were analyzed. The mean age of the study group was 59.17 ± 10.65 years. Majority of the participants (76.4%) were from rural areas. Out of 161 participants, 23 had bilateral dense cataracts. Preoperative B-scan ultrasonography assessment in 184 eyes showed posterior vitreous detachment (n = 40), retinal detachment (n = 2), vitreous hemorrhage, posterior staphyloma, and asteroid hyalosis (n = 1 each). Sensitivity and specificity of B-scan were analyzed in 173 eyes. Pearson Chi-square test showed the sensitivity of B-scan ultrasonography to be 64.2%, specificity of 100%, positive predictive value of 100%, and negative predictive value of 81.5%. Conclusions: The study showed that B-scan is a good tool for diagnosing posterior segment pathologies in patients with dense cataracts.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed187    
    Printed2    
    Emailed0    
    PDF Downloaded38    
    Comments [Add]    

Recommend this journal